substitutions:
device_name: fountain-outside
dn: fountain_outside
friendly_name: Fountain Outside
device_description: Energy Monitoring Smart Plug with button, blue LED, and red LED.
<<: !include .common.yaml
<<: !include .esp8266.yaml
<<: !include .wifi-oss.yaml
# Enable time component for use by daily power sensor
time:
- platform: homeassistant
id: homeassistant_time
binary_sensor:
- platform: gpio
pin:
number: GPIO1
mode: INPUT_PULLUP
inverted: True
name: ${friendly_name} button
on_multi_click:
- timing:
- ON for at most 1s
- OFF for at most 1s
- ON for at most 1s
- OFF for at least 0.2s
then:
- logger.log: "Double Clicked"
- switch.toggle: relay2
- timing:
- ON for 1s to 2s
- OFF for at least 0.5s
then:
- logger.log: "Single Long Clicked"
- timing:
- ON for at most 1s
- OFF for at least 0.5s
then:
- logger.log: "Single Short Clicked"
- switch.toggle: relay1
switch:
- platform: gpio
name: ${friendly_name} relay
pin: GPIO12
id: relay1
- platform: gpio
name: ${friendly_name} Light relay
pin: GPIO14
id: relay2
status_led:
pin:
number: GPIO3
# inverted: yes
sensor:
- platform: wifi_signal
name: ${friendly_name} WiFi signal
update_interval: 60s
- platform: uptime
name: ${friendly_name} uptime
# Reports the Current, Voltage, and Power used by the plugged-in device (not counting this plug's own usage of about 0.7W/0.02A, so subtract those when calibrating with this plugged into a Kill-A-Watt type meter)
- platform: hlw8012
sel_pin:
number: GPIO13
inverted: True
cf_pin: GPIO4
cf1_pin: GPIO5
current_resistor: 0.001 #The value of the shunt resistor for current measurement. Defaults to the Sonoff POWs value 0.001 ohm. Verified on https://fccid.io/2AKBP-X10S/Internal-Photos/X10S-Int-photo-4308983 that we use "R001" = 0.001 ohm
voltage_divider: 2351 #The value of the voltage divider on the board as (R_upstream + R_downstream) / R_downstream. Defaults to the Sonoff POWs value 2351. From the pic we use 2x "125" = 2x 1.2Mohm for R_upstream and "102" = 1kohm for R_downstream, so (1,200,000+1,200,000+1,000)/1,000 = 2401
# but those don't fix the measurement values, probably because we actually have a BL0937 chip instead of a HLW8012, (and part variance aswell) so we have to manually calibrate with a known load or a load and a Kill-A-Watt type meter. My values used below will only be +/-10% of yours I think.
# The comments about the voltage divider were taken from the AWP04L template. I was unable to verify the voltage divider in the Aoycocr X10S plug.
power:
name: ${friendly_name} Power
unit_of_measurement: W
id: wattage
filters:
- calibrate_linear:
# Map 0.0 (from sensor) to 0.0 (true value)
- 0.0 -> 0.0 #Need to keep 0 mapped to 0 for when connected device is not drawing any power
- 1379.1 -> 200.0 # Tested outdoor fountain pump via Kill-A-Watt
- 2816.9 -> 411.0 # Tested blow-dryer low via Kill-A-Watt
- 9250.6 -> 1341.0 # Tested water boiler via Kill-A-Watt
- 10736.7 -> 1562.0 # Tested blow-dryer high via Kill-A-Watt
current:
name: ${friendly_name} Current
unit_of_measurement: A
filters:
- calibrate_linear:
# Map 0.0 (from sensor) to 0.0 (true value)
- 0.0 -> 0.0 #Need to keep 0 mapped to 0 for when connected device is not drawing any power
- 2.07 -> 1.67 # Tested outdoor fountain pump via Kill-A-Watt
- 4.18 -> 3.41 # Tested blow-dryer low via Kill-A-Watt
- 14.37 -> 11.64 # Tested water boiler via Kill-A-Watt
- 16.26 -> 13.12 # Tested blow-dryer high via Kill-A-Watt
voltage:
name: ${friendly_name} Voltage
unit_of_measurement: V
filters:
- calibrate_linear:
# Map 0.0 (from sensor) to 0.0 (true value)
- 0.0 -> 0.0
- 355.9 -> 120.6 #Tested using a Kill-A-Watt meter, value while connected LED bulb was on
# change_mode_every: 3 # 1 - Skips first reading after each change, so this will double the update interval. Default 8
# update_interval: 3s # 10s - 20 second effective update rate for Power, 40 second for Current and Voltage. Default 60s
# Reports the total Power so-far each day, resets at midnight, see https://esphome.io/components/sensor/total_daily_energy.html
- platform: total_daily_energy
name: ${friendly_name} Total Daily Energy
power_id: wattage
filters:
- multiply: 0.001 ## convert Wh to kWh
unit_of_measurement: kWh
text_sensor:
- platform: version
name: "Fountain 1 ESPHome version"