substitutions:
|
|
duct_fan_pin: GPIO13
|
|
duct_fan_pwmfreq: 5000Hz
|
|
duct_fan_spd_name: rack_3_duct_fan_spd
|
|
amppwr_pin: GPIO19
|
|
amppwr_name: "Denon Pwr"
|
|
dallas_pin: GPIO32
|
|
dallas_in_addr: "0x7F0114328974D728"
|
|
dallas_in_name: rack_3_temp_in
|
|
dallas_out_addr: "0xB801143296ED7B28"
|
|
dallas_out_name: rack_3_temp_out
|
|
|
|
esphome:
|
|
name: rack_3
|
|
platform: ESP32
|
|
board: esp32doit-devkit-v1
|
|
|
|
wifi:
|
|
ssid: "kungle-ot"
|
|
password: "ThingsWelcomeToKungle"
|
|
|
|
manual_ip:
|
|
static_ip: 192.168.37.74
|
|
gateway: 192.168.37.1
|
|
subnet: 255.255.255.0
|
|
|
|
# Enable fallback hotspot (captive portal) in case wifi connection fails
|
|
ap:
|
|
ssid: "Rack 3 Fallback Hotspot"
|
|
password: "jj0CXEgu3Lzo"
|
|
|
|
captive_portal:
|
|
|
|
output:
|
|
- platform: ledc
|
|
pin: ${duct_fan_pin}
|
|
id: duct_fan_output_id
|
|
frequency: ${duct_fan_pwmfreq}
|
|
|
|
fan:
|
|
- platform: speed
|
|
id: duct_fan_spd_id
|
|
output: duct_fan_output_id
|
|
name: ${duct_fan_spd_name}
|
|
|
|
dallas:
|
|
- pin:
|
|
number: ${dallas_pin}
|
|
mode: INPUT_PULLUP
|
|
update_interval: 10s
|
|
|
|
sensor:
|
|
- platform: dallas
|
|
address: ${dallas_in_addr}
|
|
name: ${dallas_in_name}
|
|
- platform: dallas
|
|
address: ${dallas_out_addr}
|
|
name: ${dallas_out_name}
|
|
id: dallas_out_id
|
|
on_value:
|
|
then:
|
|
number.set:
|
|
id: fan_speed_target_out
|
|
value: !lambda |-
|
|
float lo;
|
|
float hi;
|
|
lo = id(thermostat_rack3_out).target_temperature_low;
|
|
hi = id(thermostat_rack3_out).target_temperature_high;
|
|
if (x < lo) {
|
|
return 0.0;
|
|
}
|
|
if (x > hi) {
|
|
return 100.0;
|
|
}
|
|
return 100 * (x - lo) / (hi - lo);
|
|
number:
|
|
- platform: template
|
|
id: fan_speed_target_in
|
|
name: Fan Speed Target In
|
|
optimistic: true
|
|
min_value: 0
|
|
max_value: 100
|
|
step: 1
|
|
- platform: template
|
|
id: fan_speed_target_out
|
|
name: Fan Speed Target Out
|
|
optimistic: true
|
|
min_value: 0
|
|
max_value: 100
|
|
step: 1
|
|
on_value_range:
|
|
above: 25.0
|
|
then:
|
|
fan.turn_on:
|
|
id: duct_fan_spd_id
|
|
speed: !lambda |-
|
|
return x;
|
|
|
|
# Dual-point thermostat
|
|
climate:
|
|
- platform: thermostat
|
|
id: thermostat_rack3_out
|
|
name: Rack3 Out
|
|
sensor: dallas_out_id
|
|
visual:
|
|
min_temperature: 60 °F
|
|
max_temperature: 100 °F
|
|
temperature_step: 1
|
|
default_mode: auto
|
|
default_target_temperature_low: 75 °F
|
|
default_target_temperature_high: 100 °F
|
|
min_cooling_off_time: 60s
|
|
min_cooling_run_time: 60s
|
|
min_heating_off_time: 60s
|
|
min_heating_run_time: 60s
|
|
min_idle_time: 60s
|
|
heat_action:
|
|
- logger.log: "Turning off Rack3 Thermostat"
|
|
- fan.turn_off:
|
|
id: duct_fan_spd_id
|
|
idle_action:
|
|
- logger.log: "Turning on Rack3 Thermostat"
|
|
cool_action:
|
|
- logger.log: "WARNING: Rack3 Thermostat has hit high temp!"
|
|
#TODO - provide some kind of warning / action here
|
|
|
|
# Sense when receiver is turned on
|
|
binary_sensor:
|
|
- platform: gpio
|
|
pin: ${amppwr_pin}
|
|
name: ${amppwr_name}
|
|
device_class: power
|
|
# on_press:
|
|
# then:
|
|
# - if:
|
|
# condition:
|
|
# lambda: 'return id(${duct_fan_spd_id}).state == "OFF";'
|
|
# then:
|
|
# - logger.log: "${duct_fan_spd_name} was off. Turning on as ${amppwr_name} turned on."
|
|
# - fan.turn_on:
|
|
# id: ${duct_fan_spd_id}
|
|
# speed: LOW
|
|
# else:
|
|
# - logger.log: "${amppwr_name} turned on, but not turning on ${duct_fan_spd_name} as already on."
|
|
|
|
# on_release:
|
|
# then:
|
|
# - fan.turn_on:
|
|
# id: ${duct_fan_spd_id}
|
|
# speed: LOW
|
|
|
|
# - lambda: |-
|
|
# if (id(${duct_fan_spd_id}).is_off) {
|
|
|
|
|
|
|
|
# Enable logging
|
|
logger:
|
|
|
|
# Enable Home Assistant API
|
|
api:
|
|
|
|
ota:
|